logo

rincian produk

Created with Pixso. Rumah Created with Pixso. Produk Created with Pixso.
Bangku pengujian meter stasioner
Created with Pixso.

High-Precision Meter Test Bench for Accurate Electric Meter Calibration

High-Precision Meter Test Bench for Accurate Electric Meter Calibration

Nama merek: GENY
Nomor Model: YC1893D
MOQ: 1 pcs
harga: Bisa dinegosiasikan
Ketentuan Pembayaran: L/c, t/t, d/p
Kemampuan Penyediaan: 30 pcs per bulan
Informasi detil
Tempat asal:
Cina
Sertifikasi:
ISO, CE
Penggunaan:
Pengukur Energi Multi-Fungsional, Pengukur Watt-Jam, Pengukur untuk Industri dan Penggunaan Rumah, P
Rentang tegangan output:
24V hingga 288V
Teori:
Meteran Elektronik
Output Range Arus::
1MA hingga 120A (hingga 230A Max)
Kemasan rincian:
Kasing kayu lapis
Menyediakan kemampuan:
30 pcs per bulan
Menyoroti:

electric meter calibration test bench

,

stationary meter test equipment

,

high-precision meter calibration bench

Deskripsi Produk

High-Precision Meter Test Bench for Accurate Electric Meter Calibration


Key Features


  • Accurate measurement of active/reactive power and energy

  • Supports start-up and no-load (creep) testing

  • Automatic marking for fast and efficient tests

  • Error analysis: basic error, average error, standard deviation, 24-hour drift

  • Tests voltage, frequency, harmonic (2nd-21st), and phase sequence effects

  • Simultaneous current testing for multiple meters on one rack

  • Non-disconnect testing for voltage and current circuits

  • Built-in protection for current open-circuit and voltage short-circuit

  • Integrated optical scanner to improve efficiency

  • Motorized and manual operation modes

  • PC software for data processing, storage, and report generation

  • Barcode input support

  • Durable mechanical design

  • Configurable from 3 to 60 meter positions


Specifications


  • Input Voltage: AC 220V ±10%, 50Hz ±2Hz

  • Operating Temperature: -10°C to +40°C

  • Operating Humidity: 35% to 95%

  • Output Voltage Range: 24V to 288V

  • Maximum Output Voltage Power: 1000VA

  • Voltage Resolution: 0.01%

  • Voltage Stability: 0.02% per 120 seconds

  • Load Variation Rate: 0.01%

  • Voltage Distortion: ≤0.3% (full linear load range)

  • Output Current Range: 1mA to 120A (up to 230A max)

  • Maximum Output Current Power: 2000VA

  • Current Resolution: 0.01%

  • Current Stability: 0.02% per 120 seconds

  • Load Variation Rate: 0.01%

  • Current Distortion: ≤0.3% (full linear load range)

  • Continuous Current: 100A

  • Phase Adjustment Range: 0° to 360°

  • Phase Resolution: 0.01°

  • Frequency Adjustment Range: 45Hz to 65Hz

  • Frequency Resolution: 0.01Hz

  • Power Output Stability: 0.02% per 120 seconds



High-Precision Meter Test Bench for Accurate Electric Meter Calibration 0